Elementy elektroniczne

Common Mode Toroid Chokes

The rising demand for higher power in less space, leading to higher switching frequencies and tighter packaging, also brings new challenges for EMC filtering components.

Our common mode filter chokes are designed to meet the EMC regulations even in difficult environments. All chokes have the release according to EN 138100 resp. DIN EN60938-2 (VDE 0565 type 2-1).

All thermoplastic materials used are UL94-V0 listed.

Outstanding characteristics

  • broad damping characteristic
  • good attenuation of symmetrical and asymmetrical noises
  • high temperature range (class B, 130 °C)
  • low sensitivity to saturation
 Range RDS | Style 1528 | vertical  
 Order no.  Nominal current Nominal inductance DC resistance RDS 1528 Kaschke
  [A] [mH] [Ω]
043.200  0,3  27  1,5
043.201  0,3  18  1,4
043.202  0,3  15  1,1
043.203  0,4  10  0,7
043.204  0,5  6,8  0,45
043.205  0,6  4,7  0,3
043.206  0,7  3,9  0,25
043.207  0,8  2,7  0,2
043.208  1  2,2  0,12
043.209  1,1  1,5  0,1

A = Start of winding • E = End of winding

General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.
Alternative parameters on request.

 Range RDS | Style 1517 | also available in SMD  
 Order no.  Nominal current Nominal inductance DC resistance RDS 1517 Kaschke
  [A] [mH] [Ω]
044.201  0,3  18 0,9
044.202  0,3  15 0,7
044.203  0,4  10 0,5
044.204  0,5  6,8 0,3
044.205  0,6  4,7 0,25
044.206  0,6  3,9 0,2
044.207  0,7  2,7  0,15
044.208  0,9  2,2  0,09
044.209  0,9  1,5  0,08

A = Start of winding • E = End of winding

General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.
Alternative parameters on request.

 

 Range RDS | Style 053 | vertical   
 Order no.  Nominal current Nominal inductance DC resistance Kaschke RDS 053 Vertical
  [A] [mH] [Ω]
 049.625  0,3  47  2     
    
 049.659  0,4  39  1,6
 049.651  0,5  27  1,1
 049.652  0,6  15  0,8
 049.670  0,7  10  0,65
 049.674  1,2  6,8  0,31
 049.653  1,2  5,6  0,28
 049.671  1,5  3,3  0,18
 049.654  1,5  2,7  0,13
049.672 2 1  0,07
049.668 2,6 0,4  0,05

A = Start of winding  ·  E = End of winding

General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.
Alternative parameters on request.

Range RDS | Style 1427 | horizontal   
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1427 horizontal  
  [A] [mH] [Ω]  
049.409 0,3 47 1,8
049.404 0,4 39 1,6
049.406 0,5 27 1,1
049.403 0,6 15 0,7
049.410 0,7 10 0,5
049.411 1,2 6,8 0,28
049.405 1,5 3,3 0,17
049.412 2 1 0,06
049.413 2,6 0,4 0,035

A = Start of winding • E = End of winding

General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.
Alternative parameters on request.

Range RDS | Style 055 | vertical   
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 055 vertical
 
  [A] [mH] [Ω]
049.755 0,5 47 1,7
049.770 0,5 39 1,2
049.751 0,8 27 6
049.752 1 18 0,4
049.771 1 15 0,4
049.772 1,2 10 0,35
049.753 1,5 5,6 0,2
049.754 2,2 2,7 0,09
049.773 3 1,2 0,05

A = Start of winding • E = End of winding
General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.

Alternative parameters on request.

Range RDS | Style 1178 | horizontal  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1178 horizontal  
  [A] [mH] [Ω]
049.201 0,4 47 1,7
049.220 0,5 39 1,2
049.202 0,5 27 0,9
049.210 0,7 33 0,8
049.221 1 15 0,5
049.203 1,2 10 0,35
049.222 1,5 6,8 0,25
049.204 2 2,2 0,1
049.205 3 1,2 0,05

A = Start of winding  ·  E = End of winding

General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%.
Alternative parameters on request.

 

Range RDS | Style 1428 | vertical  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1428 vertical  
  [A] [mH] [Ω]
049.908 0,5 56 1,6
049.909 0,6 39 1,1
049.906 1 27 1,65
049.900 1,2 15 0,3
049.901 1,6 10 0,22
049.904 2 6,8 0,14
049.903 4 3,3 0,045

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.

Range RDS | Style 1179 | horizontal  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1179 horizontal  
  [A] [mH] [Ω]
049.251 0,5 56 1,6
049.258 0,6 39 1,1
049.252 1 27 0,65
049.271 1,2 15 0,3
049.272 1,6 10 0,22
049.253 2 2,6 0,16
049.274 2 6,8 0,14
049.254 4 2,7 0,056
049.273 4 3,3 0,06
049.267 6 1,5 0,015

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.

Range RDS | Style 1527| vertical  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1527 vertical  
  [A] [mH] [Ω]
043.800 0,6 56 1,3
043.801 0,7 39 0,9
043.802 1,1 27 0,5
043.803 1,4 15 0,3
043.804 1,7 10 0,22
043.805 2,2 6,8 0,15
043.806 4 3,3 0,045
043.807 4,5 2,2 0,03
013.808 5 1,2 0,02

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.

Range RDS | Style 1200 | vertical  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1200 vertical  
  [A] [mH] [Ω]
049.851 0,5 82 1,8
049.858 0,8 49 1,2
049.852 1 33 0,6
049.802 1,4 27 0,4
049.853 1,6 18 0,27
049.859 2 10 0,2
049.854 2 6,8 0,17
049.855 4 3,3 0,06
049.857 6 2 0,03
049.856 6 1,2 0,02

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.

Range RDS | Style 1180 | horizontal  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1180 horizontal  
  [A] [mH] [Ω]
049.301 0,5 82 1,8
049.307 0,8 49 1,2
049.302 1 33 0,6
049.332 1,4 27 0,4
049.331 1,6 18 0,27
049.333 2 10 0,2
049.303 2 6,8 0,17
049.304 4 3,3 0,06
049.335 6 2 0,03
049.334 6 1,2 0,02

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.

Range RDS | Style 1181 | horizontal  
Order no. Nominal current Nominal inductance DC resistance Kaschke RDS 1181 horizontal  
  [A] [mH] [Ω]
049.351 1 68 1,3
049.352 2 18 0,3
049.353 4 6,8 0,08
049.354 6 3,9 0,043
049.355 8 2,7 0,023
049.356 10 1,8 0,014

A = Start of winding • E = End of winding General datas: Nominal current: RMS value, ambient temperature 60 °C. Inductance: measured at 10 mHz, 50 mV. Tolerance +50/-30%. DC resistance: nominal value at 25 °C, tolerance +10%. Alternative parameters on request.